    IEC60068-2-1 High And Low Temperature Rapid Change Test Chamber 150L

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN885-150L
    Certification : Calibration Certificate(Cost Additional )
    Price : Customized
    Payment Terms : T/T
    Supply Ability : 10 sets per month
    Delivery Time : 45 Days
    • Product Details
    • Company Profile

    IEC60068-2-1 High And Low Temperature Rapid Change Test Chamber 150L


    High and low temperature rapid change test chamber


    Product information:


    This High and low temperature rapid change test chamber is designed and manufactured according to IEC60068-2-1, IEC60068-2-2, IEC60068-2-78 and IEC60068-2-30.
    It is used to process cold, heat, humidity and dryness testing of raw materials and devices such as Parts and materials for electronic appliances, food, automobiles, rubber and plastic materials, metals and other products, such as optical fiber, LCD, crystal, inductor, PCB, battery, computer, mobile phone, rubber, plastic, etc. The purpose is to confirm the reliability of storage, transportation and use of products under high and low temperature rapid alternating humid heat environment.


    Technical parameter:


    Test Environment Conditions


    · Ambient temperature: 5~35°C

    · Relative humidity: ≤85% RH

    · Air pressure: (86~106) kPa

    Testing Method

    Temperature test equipment

    Wet heat test equipment (for wet heat type only)

    Temperature Range-40℃~+150℃
    Temperature Fluctuation≤±1.0℃ (≤±0.5℃, as per GB/T5170-2008 specification)
    Temperature Deviation±2.0℃
    Temperature Uniformity≤2.0℃
    Temperature Rise Time-40°C to +150°C, linear rate ≥ 15°C/min (no load)
    Temperature Drop Time+150°C to -40°C, linear rate ≥ 15°C/min (no load)
    Controller Model7-inch
    Operating ModeProgram mode, fixed value mode
    Setting MethodEnglish menu, touch input
    Setting RangeTemperature: Adjusted according to the device's operating temperature range (Upper limit +5℃, Lower limit -5℃)
    Display Resolution

    · Temperature: 0.01℃

    · Time: 0.01 minutes

    InputPT100 thermistor (platinum resistance/voltage/current, etc., as required by the device)
    Control MethodTemperature uses anti-integral-saturation PID with auto-tuning function

    Structural Systems:


    Insulation Enclosure Structure

    Outer Wall Material: 1.2mm double-sided electrolytic plate, surface spray-painted

    Inner Wall Material: 1.0mm stainless steel plate SUS304

    Box Insulation Material: Rigid polyurethane foam + rock wool

    Door Insulation Material: Rock wool

    Air Regulation Channel

    Axial Flow Fans: 2 unitsHeaters, Evaporator (also functions as dehumidifier),Water Drainage and Supply Ports,Dry Bulb,Temperature Sensor

    For Wet Heat Type: Includes humidifier, dry-burn protection, wet bulb temperature sensor

    Standard Configuration of Test Chamber

    Observation Window: Transparent electric heat film, double-glazed tempered glass (1 unit, located on the door)

    Visible Area: W430mm × H550mm (including lighting and obstruction areas, as shown in the device outline diagram)

    Lead Hole: φ50mm (1 unit on each side of the box)

    Sample Rack: Stainless steel, 2-tier, load capacity (evenly distributed): 20kg per tier

    Lighting: 7W/DC24V (1 unit)

    Mobile Casters: 4 units

    Door

    Single-opening Hinged Door: Left hinge, right handle

    Includes Observation Window, Lighting, and Defogging Heater for Window/Frame

    Control Panel

    Temperature control display screen

    Over-temperature protection setting device

    Emergency stop switch

    Operation indicator light

    Fault indicator light

    Buzzer

    Mechanical RoomIncludes: Refrigeration unit, drainage system, fan, power distribution control cabinet,Humidification and humidity measurement control devices
    Power Distribution Control Cabinet

    Cooling fan

    Power distribution board

    RS-485 physical interface

    Main power circuit breaker

    Heaters

    Material: 316 stainless steel armored heating element

    Control Method: Non-contact pulse width modulation, SSR (Solid-State Relay)


    IEC60068-2-1 High And Low Temperature Rapid Change Test Chamber 150LIEC60068-2-1 High And Low Temperature Rapid Change Test Chamber 150LIEC60068-2-1 High And Low Temperature Rapid Change Test Chamber 150L


    Quality IEC60068-2-1 High And Low Temperature Rapid Change Test Chamber 150L for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)