Sign In | Join Free | My himfr.com
Home > Energy Efficiency Lab >

60K BTU Double Code Air - Enthalpy Method Calorimeter ISO 5151

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 60K BTU Double Code Air - Enthalpy Method Calorimeter ISO 5151 from wholesalers
     
    Buy cheap 60K BTU Double Code Air - Enthalpy Method Calorimeter ISO 5151 from wholesalers
    • Buy cheap 60K BTU Double Code Air - Enthalpy Method Calorimeter ISO 5151 from wholesalers
    • Buy cheap 60K BTU Double Code Air - Enthalpy Method Calorimeter ISO 5151 from wholesalers
    • Buy cheap 60K BTU Double Code Air - Enthalpy Method Calorimeter ISO 5151 from wholesalers
    • Buy cheap 60K BTU Double Code Air - Enthalpy Method Calorimeter ISO 5151 from wholesalers

    60K BTU Double Code Air - Enthalpy Method Calorimeter ISO 5151

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN331C-60KD
    Certification : Calibration Certificate (Cost Additional)
    Price : Tailored
    Payment Terms : T/T
    Supply Ability : 1 Set Per Month
    Delivery Time : 3 Months
    • Product Details
    • Company Profile

    60K BTU Double Code Air - Enthalpy Method Calorimeter ISO 5151


    60K BTU Double Code Air-Enthalpy Method Calorimeter ISO 5151


    System introduction:

    This air enthalpy method calorimeter lab consists of 1 indoor side room (Room A) and 1 outdoor side room (Room B). The refrigerating capacity, heating capacity and other performances of an air conditioner are tested by means of testing the lab parameters, such as temperature, pressure and electrical performance. This installation can be used to test the performance of various window type, split type, free-standing type and ceiling cassette type and duct type AC air conditioners, and can also be used for other standard operating condition related tests and expanded tests, meeting the need for product sampling inspection and product development. The laboratory is equipped with two stations, which can simultaneously test two sets of 1-Phase prototypes not larger than 30KBtu (to ensure total not large than 60K BTU), if only test one set of prototype once, then prototype can up to 60K BTU, but should not larger than 60K BTU.


    In this test system, the operation of the equipment is controlled by a programmable controller and a HMI, test running data are collected by a high accuracy data collector, the data can be transferred at real time to an upper level computer for processing, the computer displays, stores, outputs and prints test reports.

    Testing items:

    ► Rated cooling capacity (T1, T2, T3).

    ► Rated heating capacity (High, Low, Extra-low)

    ► Airflow

    ► Dehumidification capacity

    ► Input power

    ► EER(COP)

    ► Frequency

    ► Current

    ► Voltage

    Types of UUT and environment:

    ► Types of unit under test (UUT)

    -Split type

    -Window type

    -Free-standing type

    -Ceiling cassette type

    -Duct type

    -Inver-frequency air condition


    ► Measurement range of UUT

    -Testing Capacity Range:

    -Total Cooling Capacity: 6000~60000Btu/h

    A station Cooling Capacity: 6000~60000Btu/h

    B station Cooling Capacity: 6000~30000Btu/h

    -Heating Capacity: 6000~60000Btu/h

    A station Heating Capacity: 6000~60000Btu/h

    B station Heating Capacity: 6000~30000Btu/h


    -Range of air flow:

    -Air Flow A : 300~4000 m³/h

    Air Flow B : 200~2000 m³/h

    -Figure size:Window Type:W:Under 1000mm D:Under 800mm H:Under 1000mm

    Split Type:W:Under 1000mm D:Under 500mm H:Under 2000mm

    -The electric parameter:

    -Single phase power: 0~5kW

    -Single phase voltage: 0~300V

    -Single phase current: 0~20A

    -Frequency: 50/60Hz

    -Power factor: 0~1


    Major test conditions
    NoTesting ItemIndoor side(℃)Outdoor side(℃)
    Dry BulbWet BulbDry BulbWet Bulb
    1Rating CoolingT127193524
    T221152719
    T329194624
    2Maximum CoolingT132234832
    T227193524
    T332235231
    3Freeze-upT121152115
    T22115108
    T321152115
    4Minimum Cooling21151812
    5Enclosure Sweat27242724
    6Rating HeatingHigh201576
    Low201521
    Extra Low108-5-6
    7Maximum Heating27192418
    8Minimum Heating2015-7-8
    9Automatic Defrost201221

    Sinuo is a diversified high-tech enterprise integrating testing equipment, scientific research and teaching equipment, and various non-standard customized equipment, integrating independent R&D and design, production and sales, installation and commissioning, and after-sales maintenance. Our technical staff has accumulated a wealth of practical experience.


    60K BTU Double Code Air - Enthalpy Method Calorimeter ISO 5151


    Quality 60K BTU Double Code Air - Enthalpy Method Calorimeter ISO 5151 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message: