Sign In | Join Free | My himfr.com
Home > Medical Device Testing Equipment >

28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber from wholesalers
     
    Buy cheap 28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber from wholesalers
    • Buy cheap 28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber from wholesalers
    • Buy cheap 28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber from wholesalers
    • Buy cheap 28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber from wholesalers
    • Buy cheap 28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber from wholesalers

    28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN122602
    Certification : Calibration Certificate (Cost Additional)
    Price : Negotiable
    Payment Terms : T/T, L/C, Western Union, MoneyGram
    Supply Ability : 10 Sets Per Month
    Delivery Time : 20 Days
    • Product Details
    • Company Profile

    28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber


    Face Mask Bacterial Filtration Efficiency (BFE) Test Chamber


    Facial Mask Tester Bacterial Filtration Efficiency (BFE) Test Chamber 28.3 L/Min Sampling Flow


    Product overview:


    The main performance indicators of the mask bacterial filtration efficiency (BFE) tester not only meet the requirements of B.1.1.1 of YY0469-2011 Annex B bacterial filtration efficiency (BFE) test method, but also comply with the requirements stipulated in American ASTM 2100, ASTMF2101 and European EN14683 standards. Innovative improvements have been made on this basis. The simultaneous sampling method with dual gas channels has been used to improve the accuracy of sampling. It is suitable for the measurement and verification departments, scientific research institutes, mask manufacturing enterprises and other relevant departments to measure the filtering efficiency of mask bacteria.


    Equipment Features:

    1. Negative pressure experiment system to ensure the safety of operators
    2. Built-in peristaltic pump in negative pressure cabinet, A / B two-way six-stage Andrsen sampler
    3. Flow rate of peristaltic pump can be set
    4. The spray flow rate of bacteria liquid of special microbial aerosol generator can be set
    5. Good atomization effect
    6. Embedded high-speed industrial microcomputer control
    7. 10.4 inch industrial-grade high-brightness color touch screen
    8. USB interface, support U disk data transfer
    9. Built-in high-brightness lighting lamp
    10. Built-in leakage protection switch to protect the safety of operators
    11. The inner layer of stainless steel is integrally processed and formed, and the outer layer is sprayed with cold-rolled sheet
    12. Insulation between inner and outer layers, flame retardant
    13. Front opening and closing glass door, convenient for laboratory personnel to observe and operate
    14. Removable bracket with adjustable bracket height
    15. Support, mobile dual-use casters
    Technical parameters:
    Main ParametersRangeResolutionMax. Allowed Error
    Sample flow rate of channel A28.3 L/min0.1 L/minBetter than ±2.5%
    Sample flow rate of channel B28.3 L/min0.1 L/minBetter than ±2.5%
    Spray Flow(8~10)L/min0.1 L/minBetter than ±2.5%
    Peristaltic Pump Flow(0.006~3.0)mL/min0.001 ml/minBetter than ±2.5%
    Front Pressure in of Flowmeter A(-20~0)kPa0.01kPaBetter than ±2.5%
    Front Pressure in of Flowmeter B(-20~0)kPa0.01kPaBetter than ±2.5%
    Front Pressure of Spray Flowmeter(0~300)kPa0.1kPaBetter than ±2.5%
    Aerosol Negative Pressure(-90~-120)Pa0.1PaBetter than ±2.5%
    Working Temperature(0~50)℃
    Cabinet Negative Pressure(-50~-200)Pa
    Data Storage Capacity>10000 groups
    High Efficiency Air Filter CharacteristicsFiltration efficiency for particles above 0.3um ≥99.99%
    Aerosol Generator Mass Median DiameterAverage particle diameter (3.0 ± 0.3) um, geometric standard deviation≤1.5
    Two-way 6-level Anderson Sampler Captures Particle SizeⅠlevel>7um, Ⅱ level (4.7~7) um,Ⅲ level (3.3~4.7) um,Ⅳ level(2.1~3.3)um,Ⅴ level(1.1~2.1)um, Ⅵ level(0.6~1.1)um
    Aerosol Chamber Specifications(Length 600 * diameter 85 * thickness 3) mm
    Total Number of Positive Quality Control Sampler Particles(2200±500)cfu
    Ventilation Flow of Negative Pressure Cabinet≥5m³/min
    Negative Pressure Door Size(Length 1000 * width 730) mm
    Equipment Size(Length 1180 * Width 650 * Height 1300) mm
    Bracket Size(Length 1180 * Width 650 * Height 600) mm, height adjustable within 100mm
    Working Power SupplyAC 220V±10%, 50Hz
    Equipment Noise<65dB(A)
    Equipment WeightApprox. 150kg
    Equipment Power<1500W

    28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber 28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber


    Quality 28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)