Sign In | Join Free | My himfr.com
Home > Energy Efficiency Lab >

IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber from wholesalers
     
    Buy cheap IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber from wholesalers
    • Buy cheap IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber from wholesalers
    • Buy cheap IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber from wholesalers
    • Buy cheap IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber from wholesalers

    IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN335A
    Certification : Calibration Certificate (Cost Additional)
    Price : Tailored
    Payment Terms : T/T
    Supply Ability : 1 Set Per Month
    Delivery Time : 3 Months
    • Product Details
    • Company Profile

    IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber


    IEC 60879-2019 Ceiling Fans Environmental Test Chamber Energy Efficiency Testing Lab


    Overview:


    This test laboratory can perform the performance test of the fans in accordance with the methods specified in IEC 60879-2019 and GB / T 13380-2007. The test system can accurately measure the performance parameters such as the wind speed, air volume, fan speed, fan power consumption, fan energy efficiency value of ceiling fans and decorative ceiling fans, and can realize the sampling and analysis of fan products, product quality inspection, and research and development requirements.


    It is a comprehensive single enthalpy difference chamber. The laboratory contains a set of air volume measuring devices. The test chamber uses 100mm thick rigid polyurethane board and 0.6mm thick color steel plates on both sides for thermal insulation, which has good thermal insulation effect.

    This test room contains an external air conditioning system, which is used to adjust the air environment inside the test room. The indoor air is cooled, humidified, and heated to make the temperature and humidity in the test room meet the requirements of the test conditions.

    This laboratory needs to be equipped with an operating room for storing office computers, power cabinets, control cabinets, and variable frequency power supplies. This house can be constructed by boards, which is constructed by the buyer (generally next to the laboratory).

    This test system is mainly controlled by computer. The operator is outside the test room, and the personnel will not affect the wind field. The test of the equipment is completed automatically, and the test data is recorded, saved, and the air flow report and energy efficiency rating are automatically generated. This system has advantages of good repeatability, high efficiency, convenient data storage and so on.


    Standards:


    Can be designed according to the following standards:

    IEC 60879-2019 "Comfort fans and regulators for household and similar purpose- Methods for Measuring Performance "

    GB/T 12021.9-2008 "Minimum allowable values of energy efficiency and energy efficiency grades for AC electric fans "

    GB/T 13380-2007 “A.C. electric fans and regulators”


    Types of UUT :


    *Ceiling fan:900~1800mm


    Test Contents:


    * Wind speed
    * Wind volume
    * Rotating speed
    * Speed ratio
    * input power
    * Energy efficiency value


    Laboratory Measurement Instrument Indicators:

    No.:NameContentRangeMeasurement uncertainty
    1Temperature and humidity sensorDry bulb temperature0~50℃±0.1℃
    2Temperature and humidity sensorRelative humidity30%~80%RH±3%RH
    3Digital Power MeterInput electrical parameters/±0.5%
    4AnemometerWind speed0.15~5m/s±0.2m/s

    Laboratory Room Structure:


    External dimensions4700(W)×4700(D)×3100(H)
    Inner dimensions4500(W)×4500(D)×3000(H)
    Laboratory maintenance structure100mm Rigid polyurethane foam insulation
    DoorInside 1600×2200(H)×1 (Sliding doors)
    Laboratory window size1600×800mm

    Experimental Measuring Device:


    DeviceTypeSpecifications
    LaboratoryAnemometer guideStepper motor controlJapan SanRex or equivalent, with a maximum travel distance of 2m
    Ceiling fan guideStepper motor controlJapan Matsushita or equivalent
    Sample holderHeight adjusted by screwCustomized

    Main Technical Parameters:


    1. Lifting range of sample stage: 900-1800mm.
    2. Distance between anemometer and sample:1500mm.
    3. The anemometer slide moves along four diagonal lines: 40-1000mm (automatic adjustment).
    4. Wind speed measuring instrument: Brand: Austria E + E, display decimal point: 0.01m / s, instrument accuracy: ± 0.2m / s
    5. Impeller diameter: 100 mm
    6. Measuring range: 0.40 ~ 30.00m / s
    7. Measurement accuracy: ± 1% of reading + 1% of range
    8. Wind speed sensitivity: better than 0.15m / s
    9. Temperature probe: range 0 ~ + 50 ℃; accuracy ± 0.5 ℃
    10. Driving mode: domestic servo motor + guide shaft.
    11. Control method: computer control.
    12. Collect data: power value and wind speed value.
    13. Data processing: Automatic calculation of average wind speed, air volume, energy efficiency value, and energy efficiency rating.
    14. Data storage and reference function.


    Ceiling fan test principle and method:


    1. First, install the ceiling fan through the ceiling fan lifting column, and arrange the anemometer device below 1500mm from the fan blade plane.

    2. Adjust the temperature in the test chamber to meet the test conditions (20 ° C), and start the test after running the fan for 1h.

    3. Before testing, it is also necessary to close the air inlets and outlets, doors and windows, and relevant personnel to leave the laboratory to ensure that the laboratory is not affected by external airflow. Then operator runs the anemometer to start collecting anemometer parameters. The anemometer device is rotated by 90 ° per minute to collect and record data (wind speed, speed, etc.) under the action of the rotating drive frame. (The data of wind speed ≥9m / min tested in all anemometers is valid data).

    The laboratory is equipped with a regulated power supply, which can reduce the impact of mains fluctuations on test measurements. Fan power voltage current is measured by a 0.5-level power meter.

    IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber


    Quality IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)