Sign In | Join Free | My himfr.com
Home > Battery Testing Equipment >

IEC62133-1 20V 30A Battery Testing Equipment For Lithium Ion Battery / Cell Charge Discharge Capacity Test

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap IEC62133-1 20V 30A Battery Testing Equipment For Lithium Ion Battery / Cell Charge Discharge Capacity Test from wholesalers
     
    Buy cheap IEC62133-1 20V 30A Battery Testing Equipment For Lithium Ion Battery / Cell Charge Discharge Capacity Test from wholesalers
    • Buy cheap IEC62133-1 20V 30A Battery Testing Equipment For Lithium Ion Battery / Cell Charge Discharge Capacity Test from wholesalers
    • Buy cheap IEC62133-1 20V 30A Battery Testing Equipment For Lithium Ion Battery / Cell Charge Discharge Capacity Test from wholesalers

    IEC62133-1 20V 30A Battery Testing Equipment For Lithium Ion Battery / Cell Charge Discharge Capacity Test

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SNBT4008FA-20V30A
    Certification : Calibration Certificate (Cost Additional)
    Price : Customized
    Payment Terms : T/T, L/C, Western Union, MoneyGram
    Supply Ability : 10 Sets Per Month
    Delivery Time : 1 Month
    • Product Details
    • Company Profile

    IEC62133-1 20V 30A Battery Testing Equipment For Lithium Ion Battery / Cell Charge Discharge Capacity Test

    IEC62133-1 20V 30A Charge Discharge Capacity Lithium Ion Battery And Cell Test Equipment

    Overview:

    This battery charge discharge testing equipment meets the requirements of battery and cell pulse charge and discharge test, DC internal resistance (DCIR) test, cycle life (Cycle Life) test, rate charge and discharge test. This testing equipment comes with unique software, which can run on computer to achieve romote control and minitor.
    This series of battery testing systems are widely used in various research institutions, universities and power battery manufacturers.

    Standards & Clauses:

    Conforms to IEC62133-1/-2:2017 clause 7.1, 7.2.1, 7.3.8, 7.3.9, IEC62133-1/-2:2012 clause8.1.1, 8.1.2, 8.2.1, 8.3.6, 8.3.7 IEC60086-4 clause 6.5.8 6.5.9 IEC60622, IEC60623, IEC 60086-1, IEC61951, IEC61960

    Technical Parameters:

    Project index

    Parameter index

    Input PowerAC 220V ±10% / 60Hz (can be customized)
    resolutionAD:16bit;DA:16bit
    Input Resistance≥1MΩ
    Input Power6684W
    Channel Control FeatureConstant current source and constant voltage source adopt independent double closed loop structure
    Channel Control ModeIndependent control
    VoltageVoltage Range Per Channel100mV~20V
    Minimum discharge voltage2.5V
    Accuracy± 0.1% of FS
    Constant voltage cutoff current0.06A
    Stability± 0.1% of FS
    CurrentCurrent Range Per Channel150mA~30A
    Accuracy± 0.1% of FS
    Stability± 0.1% of FS
    PowerPer Channel Output Power600W
    Stability± 0.2% of FS
    TimeCurrent Response TimeMaximum current rise time 20m S
    Step Time Range

    ≤(365*24 )hour/step,
    Time Form Support 00:00:00:000(h, min, s, ms)

    Data RecordingRecord ConditionTime△t: 100ms
    Voltage△U: 40mV
    Current△I: 60mA
    Record Frequency10Hz
    ChargeCharge ModeConstant current charging, constant voltage charging, constant current and constant voltage charging, constant current and constant voltage of the battery pack, constant power charging
    Cutoff ConditionVoltage, current, relative time, capacity, -ΔV
    DischargeDischarge ModeConstant current discharge, constant power discharge, constant resistance discharge
    Cutoff ConditionVoltage, Current, Relative Time, Capacity, -ΔV
    Pulse ModeCharge modeConstant current mode, Constant power mode
    Discharge modeConstant current mode constant power mode
    Cutoff conditionsTime, line number
    Min. pulse width500ms
    Number of pulseSingle pulse step supports 32 different pulses
    Continuous switching of charge and dischargeA pulsed step can achieve continuous switching from charge to discharge
    Cutoff conditionVoltage, relative time
    DCIR TestSupports custom point retrieval for DCR calculations
    CycleLoop Measure Range1~65535 times
    Max Steps Per Loop254
    Nested LoopNested loop Function, Max Support 3 Layers
    ProtectionSoftware Protection
    • Power-down Data Protection
    • Off-line Testing Function
    • Setting Protection Condition, Setting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time, Single cell difference
    Voltage and current detection samplingFour-wire connection
    Noise<85dB
    Noise<85dB
    DatabaseMySQL Database
    A Means of Communication of Upper MachineTCP/IP Protocol
    Data OutputEXCEL2003/2010, TXT
    Communication InterfaceEthernet Port
    Per Unit Main Channels No.8
    Dimensions12U chamber, W*D*H:600*600*1260(mm)
    FixtureTo be determined

    Equipment Working Environment:

    Project index

    Parameter index

    Working Temperature Range0℃~40℃
    Storage Temperature Range-10℃~50℃
    Working Environment Relative Humidity Range≤70% RH (No condensation)
    Storage Environment Relative Humidity Range≤80% RH(No condensation)


    The number of channels, voltage range, current range and etc. can be customized according client's specific requirements and specimen. Please email or call to Sinuo for further assistance.