Sign In | Join Free | My himfr.com
Home > Flammability Test Chamber >

Needle - Flame Testing Method Flammability Test Chamber Small Flame Effect Fire Hazad Test IEC 60695-11-5

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Needle - Flame Testing Method Flammability Test Chamber Small Flame Effect Fire Hazad Test IEC 60695-11-5 from wholesalers
     
    Buy cheap Needle - Flame Testing Method Flammability Test Chamber Small Flame Effect Fire Hazad Test IEC 60695-11-5 from wholesalers
    • Buy cheap Needle - Flame Testing Method Flammability Test Chamber Small Flame Effect Fire Hazad Test IEC 60695-11-5 from wholesalers
    • Buy cheap Needle - Flame Testing Method Flammability Test Chamber Small Flame Effect Fire Hazad Test IEC 60695-11-5 from wholesalers
    • Buy cheap Needle - Flame Testing Method Flammability Test Chamber Small Flame Effect Fire Hazad Test IEC 60695-11-5 from wholesalers
    • Buy cheap Needle - Flame Testing Method Flammability Test Chamber Small Flame Effect Fire Hazad Test IEC 60695-11-5 from wholesalers

    Needle - Flame Testing Method Flammability Test Chamber Small Flame Effect Fire Hazad Test IEC 60695-11-5

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN773
    Certification : Calibration Certificate (Cost Additional)
    Price : Negotiable
    Payment Terms : T/T, L/C, Western Union, MoneyGram
    Supply Ability : 10 Sets Per Month
    Delivery Time : 20 Days
    • Product Details
    • Company Profile

    Needle - Flame Testing Method Flammability Test Chamber Small Flame Effect Fire Hazad Test IEC 60695-11-5

    IEC 60695-11-5 Needle-flame Testing Method Small Flame Simulation Fire Hazad Test Appratus


    Overview:


    This needle flame test is used to simulate the effect of small flames that may arise in malfunctioning electrical equipment.


    The burner which produces the 12 mm high test flame shall consist of a tube at least 35 mm long with a bore of 0.5mm±0.1mm and outer diameter not exceeding 0.9mm. The burner is supplied with butane or propane gas having a purity of at least 95%. There shall be no air admitted to the burner tube. To evaluate the possibility of spread of fire, for example by burning or glowing particles falling from the test specimen, a layer of the material or components normally surrounding or situated underneath the test specimen and the surrounding material or components when the test specimen is mounted as in normal use.


    The test flame is positioned so that the tip of the flame is in contact with the surface of the test specimen. The test flame is removed after the specified time.


    If the test specimen drips molten or having flaming material during the application of the flame, the burner may be tilted up to 45°from the vertical to prevent material from dripping into the burner tube while maintaining an 8mm±1mm spacing between the centre of the top of the burner and the remaining portion of the test specimen, ignoring any strings or molten material.


    Standards:


    IEC60695-11-5

    IEC 60695-2-2


    Technical Parameters:


    Control modeButton operation + romote controller
    Display modePrecious digital meters
    Chamber StructureStainless steel plate with high-grade paint
    Button switchTop grade button
    Combustion gasButane or propane gas, purity ≥ 95%
    Flame application time0-9999.9s can be preset
    Flame duration0-9999.9s display, automatic recording
    Time resolution0.1s
    Flame temperature rising timeFrom 100℃ ± 2℃ to 700℃ ± 3℃ ( room temperature~ 999℃ ) ,23.5s±1.0s (1s ~ 999.9s)
    Flame height12mm ± 1mm ( ajustable )
    Combustion angle0°, 20°, 45° (adjustable )
    Needle burnerStainless steel,bore diameter:Φ 0.5mm ± 0.1mm,outer diameter ≤Φ 0.9mm ,length≥35mm
    Copper blockThe copper block material is specified as : Cu-ETP UNS C11000 (see ASTM-B187). The diameter of the copper block shall be 4mm 0.01mm with a mass of 0.58g 0.01g in the fullu machined and polished but undrilled state.
    ThermocoupleImported Omega brand Φ 0.5 armour nickel-chromium / nickel aluminum wire K type thermocouple, temperature resistance 1100°C
    Temperature sensing delay1.7S
    Test space≥ 0.5m³, black yogon background
    DimensionsL1100mm × W530mm × H1150mm ,Exhaust aperture:Φ100mm;
    Power supply220V /50Hz, 0.5kVA (110V, 60Hz or other power supply can be customized)
    StandardIEC60695-11-5, IEC 60695-2-2

    Application:


    This needle-flame tester is applicable to testing electrical equipment, its sub-assemblies and components, as well as solid electrical insulation materials or other combustible materials, such as lighting, low-voltage electrical appliances, household appliances, machine tool electric appliance, electric motor, electric tools, electronic instruments, electrical instruments, electrical connector, rubber, plastic materials and etc.

    Needle - Flame Testing Method Flammability Test Chamber Small Flame Effect Fire Hazad Test IEC 60695-11-5

    Quality Needle - Flame Testing Method Flammability Test Chamber Small Flame Effect Fire Hazad Test IEC 60695-11-5 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)