Sign In | Join Free | My himfr.com
Home > Environmental Test Chamber >

Walk In Constant Humidity Heat Test Chamber For Testing Solar Panel IEC60068-2

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Walk In Constant Humidity Heat Test Chamber For Testing Solar Panel IEC60068-2 from wholesalers
     
    Buy cheap Walk In Constant Humidity Heat Test Chamber For Testing Solar Panel IEC60068-2 from wholesalers
    • Buy cheap Walk In Constant Humidity Heat Test Chamber For Testing Solar Panel IEC60068-2 from wholesalers
    • Buy cheap Walk In Constant Humidity Heat Test Chamber For Testing Solar Panel IEC60068-2 from wholesalers
    • Buy cheap Walk In Constant Humidity Heat Test Chamber For Testing Solar Panel IEC60068-2 from wholesalers
    • Buy cheap Walk In Constant Humidity Heat Test Chamber For Testing Solar Panel IEC60068-2 from wholesalers

    Walk In Constant Humidity Heat Test Chamber For Testing Solar Panel IEC60068-2

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN886-4300
    Certification : Calibration Certificate(cost additional )
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 10 Sets / Month
    Delivery Time : 30 days
    • Product Details
    • Company Profile

    Walk In Constant Humidity Heat Test Chamber For Testing Solar Panel IEC60068-2


    Walk In Constant Humidity Heat Test Chamber For Testing Solar Panel IEC60068-2


    Product Information For Walk-In Corrosion Humidity-Heat Test Chamber:


    Solar panel walk-in constant temperature and humidity test chamber is mainly designed and manufactured according to standards of IEC 60068-2-78, IEC 1251:1993, IEC 61730 and etc. It is used to test photovoltaic modules and determine the ability of modules to withstand long-term moisture penetration. The purpose is to determine the ability of modules to resist heat cycles and humidity-heat tests. It is also suitable for ESS high and low temperature cyclic stress screening test or constant test for electrical and electronic products and other products, parts and materials, and for quality and reliability testing of products, parts and materials under simulated temperature changes.

    The test room adopts PLC intelligent central integrated control, touch screen display and operation, it is equipped with sample placement brackets, and a slope at the entrance of the test room. The samples are convenient to be moved and placed. The whole system is simple to operate, and the whole machine is beautiful and generous.


    Technical Parameter For Walk-In Corrosion Humidity-Heat Test Chamber:


    ItemSpecifications
    NameSolar Panel Walk-in Constant Temperature and Humidity Test Chamber
    ModelSN886-4300
    Working studio size (mm)1100×2600×1500 W*D*H
    Numbers of samples that can be placed3 pcs, Sample size not larger than 1200× 2400×45 mm W*D*H
    Chamber external size(mm)Approx. 1850×2850×2720 W*D*H
    Test RangeTemperature-40℃~+100℃
    Humidity

    20%~98%RH (Shown as following)


    Heating and cooling rateRising rate≤1.6℃/min (full average)
    Cooling rate≤1.0℃/min (full average)
    Temperature fluctuation≤±0.5℃ (at steady state)
    Temperature uniformity≤2℃ (at steady state)
    Temperature deviation±2.0℃
    Humidity Deviation

    ≤+2/-3%R.H. (when the humidity>75%R.H.)

    ≤±5%R.H. (when the humidity>≤75%R.H.)

    Test contents1. Thermal cycle: cycle from -40°C±2.0°C to 85°C±2.0°C, the temperature change rate is less than 100°C/h, the constant temperature time is at least 10min, and one cycle does not exceed 6h
    2. Humidity-heat test: 85°C±2.0°C, 85%±5%, test time 1000h
    Noise≤75dB
    WeightApprox. 1800KG
    Test method applied

    IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

    IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

    IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”

    IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”

    Note: The above performance indicators are measured at room temperature +25°C without samples.
    MaterialInner wall materialSUS304# stainless steel plate
    Outer wall materialCold rolled steel plate, pickling and phosphating advanced powder baking paint
    Insulation materialrigid polyurethane foam + glass fiber
    StructureAir duct partsCentrifugal fan; the air outlet can adjust the air volume, height and return air volume
    DoorSingle open door, with handle-type non-reaction handle, the door is equipped with an observation window, lighting lamp, window/door frame anti-condensation electric heating device, Door size: SN886-4300: (approx.) 1.1*1.5M, SN886-5800 (approx.) 1.5*1.5M
    Observation windowThe door with one conductive film explosion-proof tempered glass observation window (with anti-condensation function), window size: 500W×600H (mm)
    FanLong axis centrifugal fan
    Sample mounting rackWill be customized to match client’s sample
    ImpellerUse stainless steel impeller imported from Taiwan
    HeaterNickel-chromium alloy electric heater
    Refrigeration CompressorFrench Tecumseh compressor

    Evaporator


    Fin type evaporator
    Refrigerating methodMechanical compressor cascade
    Cooling methodAir-cooling
    Temperature control instrument10-inch smart LCD touch programmable controller
    Lead holeΦ100mm, 1 pc, equipped with a special foam rubber plug (located on the left side of the chamber)

    System Principle For Walk-In Salt Spray Corrosion Humidity-Heat Test Chamber:


    The PLC is used to control the cooling of the compressor, the heating of the heat pipe and the humidification of the humidifier, cooperating with the indoor air duct to realize the control of the temperature and humidity in the chamber.

    Forced circulation ventilation, balance temperature regulation method. The control system controls the output of the heater through the PID automatic calculation output according to the temperature point set by the system, and finally reaches a dynamic balance.



    Chamber structure For Walk-In Corrosion Humidity-Heat Test Chamber:


    The test chamber consists of a control cabinet, a chamber body, a sample mounting bracket and a slope.


    Walk In Constant Humidity Heat Test Chamber For Testing Solar Panel IEC60068-2

    Quality Walk In Constant Humidity Heat Test Chamber For Testing Solar Panel IEC60068-2 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)