Sign In | Join Free | My himfr.com
Home > Environmental Test Chamber >

IEC60068-2 Solar Panel Walk In Salt Spray Corrosion Temperature Test Chamber

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap IEC60068-2 Solar Panel Walk In Salt Spray Corrosion Temperature Test Chamber from wholesalers
     
    Buy cheap IEC60068-2 Solar Panel Walk In Salt Spray Corrosion Temperature Test Chamber from wholesalers
    • Buy cheap IEC60068-2 Solar Panel Walk In Salt Spray Corrosion Temperature Test Chamber from wholesalers
    • Buy cheap IEC60068-2 Solar Panel Walk In Salt Spray Corrosion Temperature Test Chamber from wholesalers
    • Buy cheap IEC60068-2 Solar Panel Walk In Salt Spray Corrosion Temperature Test Chamber from wholesalers
    • Buy cheap IEC60068-2 Solar Panel Walk In Salt Spray Corrosion Temperature Test Chamber from wholesalers

    IEC60068-2 Solar Panel Walk In Salt Spray Corrosion Temperature Test Chamber

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN8810-4300
    Certification : Calibration Certificate(cost additional )
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 10 Sets / Month
    Delivery Time : 30 days
    • Product Details
    • Company Profile

    IEC60068-2 Solar Panel Walk In Salt Spray Corrosion Temperature Test Chamber


    IEC60068-2 Solar Panel Walk-In Salt Spray Corrosion Temperature Test Chamber


    Product Information For Solar Panel Walk-In Salt Spray Corrosion Temperature Test Chamber:


    Solar panel walk-in constant temperature and humidity test chamber is mainly designed and manufactured according to standards of IEC60068-2-11:2021, IEC60068-2-52:2017, IEC 1251:1993, IEC 61730 and etc. It is used for the detection of photovoltaic module salt spray corrosion test; the purpose is to determine the ability of the module to resist salt spray corrosion.

    The salt spray corrosion test can evaluate the adaptability of photovoltaic module materials and the quality and uniformity of the protective layer. The sample does not need to be pretreated, and the inclination angle between the upper surface of the component where the sample is placed and the vertical direction should be 15° to 30°, and the test lasts for 96 hours.

    The test chamber adopts PLC intelligent central integrated control, touch screen display and operation, it is equipped with sample placement brackets, and a slope at the entrance of the test room. The samples are convenient to be moved and placed. The whole system is simple to operate, and the whole machine is beautiful and generous.


    Technical Parameter For Solar Panel Walk-In Salt Spray Corrosion Temperature Test Chamber:


    Chamber temperature rangeRT~55℃ continuously adjustable
    Saturated barrel temperature rangeRT+5℃~70℃
    Salt spray deposition

    1~2ml/h/80cm2 (collect at least 16 hours, take the average value)

    Note: The spray volume monitoring point is located in the test area near the surface of the sample

    Spray pressure70~170Kpa
    Spray methodContinuous spray, cycle spray, two modes can be self-adjusted
    Solution pHNeutral test 6.5~7.2, acid test 3.0~3.3
    Test conditionsNSS salt spray test, AASS acetic acid salt spray test, CASS copper accelerated acetic acid salt spray test can be performed separately
    Control precision

    Temperature Resolution: 0.1℃

    Temperature deviation: ±2.0℃

    Temperature fluctuation: ±1℃

    Note: The temperature uniformity and deviation are measured under the condition that the ambient temperature is +25℃, the relative humidity is ≤85%R.H, and no sample.

    Chamber heating rateRT→+60℃≤45 min
    Saturated barrel heating rateRT→+65℃≤45 min
    Total test time/spray time/pause time0-999.9h, can be set on the touch screen
    Sample Limit

    This test equipment prohibits:

    Testing or storage of flammable, explosive, volatile material samples

    Testing or storage of samples of corrosive substances

    Testing or storage of biological samples

    Testing or storage of samples of strong electromagnetic emission sources

    Testing and storage of radioactive material samples

    Testing and storage of samples of highly toxic substances

    Testing and storage of samples that may produce highly toxic substances during testing or storage

    Working studio size (mm)1100×2600×1500 W*D*H
    Numbers of samples that can be placed3 pcs, Sample size not larger than 1200× 2400×45 mm W*D*H
    Chamber external size(mm)Approx. 1600×3200×2700 W*D*H
    WeightApprox. 380KG
    Total power of the machine7KW

    Power Supply Conditions For Solar Panel Walk-In Salt Spray Corrosion Temperature Test Chamber:


    AC380V three-phase four-wire system + protective grounding; the allowable fluctuation range of voltage is ±10%V.

    The allowable frequency fluctuation range is 50±0.5HZ; TN-S power supply or TT power supply.

    The grounding resistance of the protective ground wire is less than 4Ω.

    The user is required to configure an air or power switch of corresponding capacity for the equipment at the installation site, and this switch must be independently used for this equipment.


    Chamber structure For Solar Panel Walk-In Salt Spray Corrosion Temperature Test Chamber:


    The inner chamber is welded by gray-white imported PVC board, and the thickness of the board is 8mm.

    The outer chamber is welded by gray-white imported PVC board, and the thickness of the board is 5mm.

    The control box and the test box are integral left and right rear structures. The left side is the test box body, and the right side is the brine tank and saturated pressure tank. The water and electricity separation structure effectively prevents water from entering the electrical control box and damaging the accessories, which is safe and reliable.

    The whole chamber is a floor-standing structure. The bottom of the equipment is welded with channel steel to form a frame structure. The bottom is equipped with movable casters and positioning cups to facilitate the movement and positioning of the chamber.

    The chamber can be well sealed to ensure that the corrosive gas in the chamber does not leak, and the sealing cover is opened by the automatic lifting method of the cylinder, which is easy to operate.


    IEC60068-2 Solar Panel Walk In Salt Spray Corrosion Temperature Test Chamber

    Quality IEC60068-2 Solar Panel Walk In Salt Spray Corrosion Temperature Test Chamber for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)