Sign In | Join Free | My himfr.com
Home > Vehicle Testing Equipment >

IEC 62196 80A Load Cabinet For Switches Plugs And Sockets Breaking Capacity Test

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap IEC 62196 80A Load Cabinet For Switches Plugs And Sockets Breaking Capacity Test from wholesalers
     
    Buy cheap IEC 62196 80A Load Cabinet For Switches Plugs And Sockets Breaking Capacity Test from wholesalers
    • Buy cheap IEC 62196 80A Load Cabinet For Switches Plugs And Sockets Breaking Capacity Test from wholesalers
    • Buy cheap IEC 62196 80A Load Cabinet For Switches Plugs And Sockets Breaking Capacity Test from wholesalers
    • Buy cheap IEC 62196 80A Load Cabinet For Switches Plugs And Sockets Breaking Capacity Test from wholesalers
    • Buy cheap IEC 62196 80A Load Cabinet For Switches Plugs And Sockets Breaking Capacity Test from wholesalers

    IEC 62196 80A Load Cabinet For Switches Plugs And Sockets Breaking Capacity Test

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN224
    Certification : Calibration Certificate (Cost Additional)
    Price : Customized
    Payment Terms : T/T
    Supply Ability : 20 sets per month
    Delivery Time : 30 Days
    • Product Details
    • Company Profile

    IEC 62196 80A Load Cabinet For Switches Plugs And Sockets Breaking Capacity Test


    IEC 62196 80A Load Cabinet for Switches Plugs and Sockets Breaking Capacity Test


    Standards & Clauses:


    This load cabinet conforms to IEC 62196-1:2020 clause 22. It is used to process breaking capacity test for plug, socket, switch, connector, relay and other parts. The load cabinet has single-phase power output and single-phase load input, and the load can be divided into resistive, inductive or capacitive loads.


    Application:


    Used to provide adjustable load voltage, current and power factor during mechanical-electrical contact system test. it is suitable for breaking capacity and normal operation endurance test of switches, plugs and socket-outlets for household and similar fixed electrical installations, and electrical stress test for luminaries and other similar tests. This series of resistive, inductive, capacitive load cabinets should work with Sinuo's plug, socket and switch endurance test equipment.

    Test station quantity can be customized:


    Technical Parameters:

    No.:ItemParameters
    1Power supplySingle phase AC220V/60Hz with ground wire
    2Channel1 channel
    3Digital voltmeter0~300V, accuracy ±0.5%
    4Digital ammeter0~82A, accuracy ±0.5%
    5Digital display power meter0~24KW, accuracy ±0.5%
    6Digital display power factor meter0.2~0.999, accuracy ±0.5%
    7Load modeResistive, inductive, capacitive three in one, switchable
    8Capacitive load70uf, 140uf, 7.3uf can be switchable
    9Load output modeEach power (continuous) / interval power can be switchable
    10Timer0~9999 times, can be preset
    11Load power capacitySingle 24KVA
    12Upper limit of output current82A, when it exceeds 82a, it will cut off automatically
    13Operating environmentTemperature: + 5 ~ + 40 ℃; relative humidity: (20 ~ 90)% RH; atmospheric pressure: 80 ~ 106kpa; no severe shaking, no vibration, no electromagnetic interference, no dust, no explosive, no corrosive gas, good heat dissipation.

    Test Principle:


    The output voltage, output current and power factor can be adjusted through the circuit combination.


    Structure:


    The load cabinet uses an integral steel structure frame and a Toyota white seal plate. The control panel is in the upper part of the equipment, there are external power supply switch, ammeter, voltmeter and power meter, power display instrument, load power supply switch, status indicators, start and stop buttons, capacitance switch, load type switch and alarm on the control panel. The voltage, current and power factor regulators are on the lower part of the equipment. Each load station has a three-in-one function of resistive, inductive and capacitive (fluorescent) load, which can be switched by a transfer switch. The interior of the load cabinet is cooled by strong wind convection. There are terminals at the bottom of the back of the load cabinet, which can be connected to the switch plug socket-out normal operation endurance test equipment through the cables to output current, voltage and power during the breaking capacity testing.


    Use Environment:


    Power supply:Single phase AC220V/60Hz with ground wire, 24 KVA/station or meet client's local power supply requirements

    Use place: atmospheric pressure 80 ~ 106kpa; ambient temperature 5 ~ 40 ° C; relative humidity (20 ~ 80) % RH; no vigorous shaking, no vibration, no electromagnetic interference, no dust, no explosive and no corrosive gas, with good heat dissipation