Sign In | Join Free | My himfr.com
Home > Switch Life Tester >

IEC 60884-1 Clause 11.5 Multimeter Electrical Safety Tester

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap IEC 60884-1 Clause 11.5 Multimeter Electrical Safety Tester from wholesalers
     
    Buy cheap IEC 60884-1 Clause 11.5 Multimeter Electrical Safety Tester from wholesalers
    • Buy cheap IEC 60884-1 Clause 11.5 Multimeter Electrical Safety Tester from wholesalers
    • Buy cheap IEC 60884-1 Clause 11.5 Multimeter Electrical Safety Tester from wholesalers
    • Buy cheap IEC 60884-1 Clause 11.5 Multimeter Electrical Safety Tester from wholesalers
    • Buy cheap IEC 60884-1 Clause 11.5 Multimeter Electrical Safety Tester from wholesalers

    IEC 60884-1 Clause 11.5 Multimeter Electrical Safety Tester

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN2212
    Certification : Calibration Certificate (Cost Additional)
    Price : Negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 15 Sets Per Month
    Delivery Time : 30 Days
    • Product Details
    • Company Profile

    IEC 60884-1 Clause 11.5 Multimeter Electrical Safety Tester


    IEC 60884-1 Clause 11.5 Multitester Electrical Safety Tester


    Product information:

    This multitester electrical safety tester Conforms to IEC 60884-1:2013 clause 11.5, 17.1, 17.2, IEC 60669-1 clause 11.4, clause 16, IEC 60950:2013 clause 2.6.3.4, 5.2 and 6.2.2.3, IEC 60335-1 Clause 10, 13, Clause 16, Clause 27 and etc. It integrates 6 functions of hi-pot, insulation, grounding, leakage, power, low-voltage start testing.


    Features:

    ■ Meet CCC, IEC, EN, VDE, BS, GS, UL and other electrical safety standards

    ■ Unlimited storage of test conditions and test results

    ■ Data can be copied via USB

    ■ Fast speed: ARM high-speed processor is used as the control core of the test instrument, and data processing is comprehensive and fast

    ■ High accuracy: safety test accuracy up to 1.5%

    ■ Ramp rise and down of voltage withstand can be set, and with upper and lower limit alarm function

    ■ Digital closed-loop feedback control mode, fully automatic voltage regulation mode, output voltage / current is automatically corrected, and it is not affected by external power grid fluctuations to ensure the accuracy of the test

    ■Two judgment modes can be chosen for ground resistance test: voltage and resistance, to meet the requirements of different national / industry standards

    ■ Built-in one human body network fora leakage current test, which can be customized to any human body network-optional function


    Technical parameters:

    Applied standardIEC 60884-1
    Applied clause11.5
    AC withstand voltage
    Output voltage setting rangeAC 200~5000V
    Output voltage accuracy

    ±(1.5%×setting+5words)

    Output voltage setting step

    1V

    Output frequency

    50/60Hz

    Output waveform

    Sine wave
    Distortion of output waveformLess than 2% (at purely resistive load)

    Output waveform adjustment rate

    Less than (2%* setting +5V)

    Output capacity

    500VA

    Output voltage ramp-down time setting range

    0~300s

    Set step

    0.1s

    Breakdown current measurement range0.10~99.99mA

    Breakdown current test accuracy

    ±(1.5%×reading+5words)

    Breakdown current preset upper limit0.10~99.99mA
    Breakdown current preset lower limit

    0.00~5.00mA

    Breakdown current preset step

    0.01mA/step

    Test time setting range

    1~300s

    Test time setting step

    1s/step
    Arc detection

    1~9 Level (level 9 is the highest sensitivity)

    Insulation resistance
    Output voltage setting rangeDC 200~1000V
    Output voltage accuracy± (1.5%×reading+5 words)
    Output voltage setting step

    1V

    Output capacity60VA
    Output voltage ramp-down time setting range0~300s

    Set step

    0.1s

    Insulation resistance measurement range / accuracy

    1~2000 MΩ ≤100 MΩ: ±(5%×displaying+3words) >100 MΩ: ±(8%×displaying+8words)
    Insulation resistance alarm setting range

    Upper limit: 0 ~ 2000MΩ; lower limit: 1 ~ 2000MΩ

    Test time range, resolution1~300s 1s/step
    Ground resistance
    Ground current output range / accuracy

    AC 5.0~30.0A

    Ground current accuracy

    ±(1.5%×setting+0.2A)

    Ground resistance measurement range

    10.0~600mΩ

    Ground resistance measurement accuracy±(1.5%×displaying+3mΩ)
    Ground resistance alarm setting rangeUpper limit: 5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ;lower limit:0.0~100mΩ

    Ground resistance setting step

    1mΩ

    Test time range

    1~300s

    Test time step1s/step
    Leakage current

    The output voltage

    1.06 times rated voltage provided by the built-in variable frequency power supply
    Leak type setting

    Dynamic leakage, static leakage, built-in one leakage current human body network, any human body network can be customized

    Output voltage measurement rangeAC 50~280V
    Output voltage frequency

    AC 45~65Hz

    Output voltage accuracy±(0.5%×displaying+2words)
    Leakage current measurement range

    0.05~20.00mA

    Leakage current measurement accuracy

    ± (1.5%× displaying +10uA)

    Leakage current setting alarm range

    Upper limit: 0.05 ~ 20.00mA; lower limit: 0.01 ~ 5.00mA

    Leakage current setting step

    0.01mA

    Test time range

    1~300s 1s/step

    Power

    Output voltage

    1.0 times rated voltage, provided by built-in variable frequency power supply

    Output voltage measurement range / accuracy

    AC 50~280V ±(0.5%×displaying+2 words)

    Output current measurement range / accuracy

    AC 0.20~30.00A ±(0.5%× displaying +2 words )

    Active power measurement range / accuracy

    30~6000W ±(0.5%× displaying +5 words )


    Power setting alarm rangeUpper limit: 3 ~ 6000W , Lower limit: 0 ~ 6000W
    Test time range / resolution1~300s 1s/step
    Low voltage start
    Output voltage0.85 times rated voltage provided by the built-in variable frequency power supply
    Output voltage measurement range / accuracy

    AC 50~280V ±(0.5%× displaying +2words)

    Starting current measurement range / accuracy

    AC 0.20~30.00A ±(0.5%× displaying +2 words )

    Current setting alarm rangeUpper limit:0.20~30.00A Lower limit: 0.00~25.00A
    Test time range

    1~300s 1s/step

    Communication

    232 485 can Bu
    Interfaces TCP / IP interface
    External control method

    PLC interface, switch signal

    System appearance

    Size:600W*1840H*600Dmm Height with pulley, alarm light
    System standard accessoriesPower cord × 1, foot switch × 1, 30A test clamp × 1, test box × 1, power input line × 1, fuse tube × 1
    Quality IEC 60884-1 Clause 11.5 Multimeter Electrical Safety Tester for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)