Sign In | Join Free | My himfr.com
Home > Water Ingress Testing Equipment >

IEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water Drops

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap IEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water Drops from wholesalers
     
    Buy cheap IEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water Drops from wholesalers
    • Buy cheap IEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water Drops from wholesalers
    • Buy cheap IEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water Drops from wholesalers
    • Buy cheap IEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water Drops from wholesalers
    • Buy cheap IEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water Drops from wholesalers

    IEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water Drops

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN442
    Certification : Calibration Certificate (Cost Additional)
    Price : Customized
    Payment Terms : T/T
    Supply Ability : 10 Sets Per Month
    Delivery Time : 30 Days
    • Product Details
    • Company Profile

    IEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water Drops


    IEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water Drops


    Product Information For IPX1 IIPX1~2 Vertical Rain Drip Test System:


    This test device is to verify Protection against Vertically Falling Water Drops. It is designed and manufactured in accordance with the standard requirement of IEC60529 IPX1 and IPX2, IEC60335-1 clause 15.etc.

    The rise and fall of the drip box is controlled by the motor. The electrical control cabinet is with PLC and touch screen.

    1. Stainless steel fine filter for dirt filtration.

    2. Adopts compressed air (compressed air should be prepared by user) to blow out the water in the needles, to prevent water reactive substances and atmospheric blocking needles.

    3. Stainless steel general medical needle nozzles, easy to buy, not easy to rust.

    4. Needle nozzles and needle nozzle seats using taper connection, can be easily replaced without the tool, individual damage to the needle nozzle can be easily replaced quickly.


    Technical Parameters :


    Item

    Specifications

    Power supply of this equipment

    Three phase AC380V, 50Hz, 4KW

    Power supply for test sample

    Single phase AC220V, 16A

    LWGYD-4 flow rate Sensors

    Flow range: 0.667-4.167 L/min, pulse output

    Small water pump

    Brand: South, model no.: CHL2-40, 380VAC, 50Hz, 0.55kw Protection class: IP55 Insulation class: F

    Waterproof test range

    IPX1 test, IPX2 test, IPX1/IPX2 custom

    IPX1-IPX2

    Drip area: 1000*1000mm

    Diameter of drip hole: 0.4mm

    Distance between each two neighbor holes:20mm

    Test flow:1~1.5mm/min(IPX1), 3~3.5mm/min(IPX2)

    Test time

    Set according to the test standard (range 1-9999 seconds), the unit is: second

    Water dripping height

    200mm (automatically controlled by the test equipment)

    Water Drainage

    Automatically emptying the tank water after the test is completed, should connected with an air source (the 0.6MPa compressed air source should be prepared by user)

    Equipment body material

    Industrial aluminum alloy

    Installation method

    Wall Mount

    Turntable

    1-5r/ min, can be set

    Control

    PLC & 7” touch screen

    Troubleshooting:


    No.:

    Failure phenomenon

    Reason of issue

    Treatment

    1

    Turn on the power switch and the touch screen does not light up

    External power supply fails

    Reconnect external power supply

    Equipment MCB is disconnected

    Turn on the equipment MCB

    2

    No action when the start button is pressed

    The run time is not cleared

    Press Count Clear

    The emergency stop switch is not reset

    Reset the emergency stop switch

    Inverter alarm

    Restart after power off

    3

    Little or no water from the needles

    Needles are clogged

    Replace the needle or remove the needle and blow through the needle hole with airflow

    4

    Unstable flow

    Air in the pipeline

    Press “Dry Drip Box” in the Manual control interface to exhaust the air, or open the vent of the water pump to exhaust the air


    IEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water DropsIEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water DropsIEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water DropsIEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water Drops


    Quality IEC60529 IPX1~2 Vertical Rain Drip Test System To Verify Water Drops for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)