Sign In | Join Free | My himfr.com
Home > Switch Life Tester >

IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions from wholesalers
     
    Buy cheap IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions from wholesalers
    • Buy cheap IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions from wholesalers
    • Buy cheap IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions from wholesalers
    • Buy cheap IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions from wholesalers
    • Buy cheap IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions from wholesalers

    IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN2212
    Certification : Calibration Certificate (Cost Additional)
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 15 Sets Per Month
    Delivery Time : 30 Days
    • Product Details
    • Company Profile

    IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions


    IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions


    Product Information For Multimeter Electrical Safety Tester:


    This multitester electrical safety tester Conforms to IEC 60598-1 clause 8.2.3, clause10.2.1, clause 10.2.2, IEC 60950:2013 clause 2.6.3.4, 5.2 and 6.2.2.3, IEC 60335-1 Clause 13, Clause 16, Clause 27 and etc. It integrates 6 functions of hi-pot, insulation, grounding, leakage, power, low-voltage start testing.


    Features For Multimeter Electrical Safety Tester:


    ■Meet CCC, IEC, EN, VDE, BS, GS, UL and other electrical safety standards

    ■Unlimited storage of test conditions and test results

    ■Data can be copied via USB

    ■Fast speed: ARM high-speed processor is used as the control core of the test instrument, and data processing is comprehensive and fast

    ■High accuracy: safety test accuracy up to 1.5%

    ■Ramp rise and down of voltage withstand can be set, and with upper and lower limit alarm function

    ■Digital closed-loop feedback control mode, fully automatic voltage regulation mode, output voltage / current is automatically corrected, and it is not affected by external power grid fluctuations to ensure the accuracy of the test

    ■Two judgment modes can be chosen for ground resistance test: voltage and resistance, to meet the requirements of different national / industry standards

    ■Built-in one human body network fora leakage current test, which can be customized to any human body network-optional function


    Technical Parameters For Multimeter Electrical Safety Tester:


    ModelFunctionsCapacityAccuracy
    SN2212ACW/IR/GB/LC/PWR/STRBuilt-in Frequency Power Supply, 5KVA1.5%
    AC withstand voltage
    Output voltage setting rangeAC 200~5000V
    Output voltage accuracy±(1.5%×setting+5words)
    Output voltage setting step1V
    Output frequency50/60Hz

    Output waveform

    Sine wave
    Distortion of output waveformLess than 2% (at purely resistive load)
    Output waveform adjustment rateLess than(2%* setting +5V)
    Output capacity500VA
    Output voltage ramp-down time setting range0~300s
    Set step0.1s
    Breakdown current measurement range0.10~99.99mA
    Breakdown current test accuracy±(1.5%×reading+5words)
    Breakdown current preset upper limit0.10~99.99mA
    Breakdown current preset lower limit0.00~5.00mA
    Breakdown current preset step0.01mA/step
    Test time setting range1~300s
    Test time setting step1s/step
    Arc detection1~9 Level (level 9 is the highest sensitivity)
    Insulation resistance
    Output voltage setting rangeDC 200~1000V
    Output voltage accuracy± (1.5%×reading+5 words)
    Output voltage setting step1V
    Output capacity60VA

    Output voltage ramp-down time setting range


    0~300s
    Set step0.1s
    Insulation resistance measurement range / accuracy1~2000 MΩ ≤100 MΩ:±(5%×displaying+3words) >100 MΩ:±(8%×displaying+8words)
    Insulation resistance alarm setting rangeUpper limit: 0 ~ 2000MΩ; lower limit: 1 ~ 2000MΩ
    Test time range, resolution1~300s 1s/step
    Ground resistance
    Ground current output range / accuracyAC 5.0~30.0A
    Ground current accuracy±(1.5%×setting+0.2A)
    Ground resistance measurement range10.0~600mΩ
    Ground resistance measurement accuracy±(1.5%×displaying+3mΩ)
    Ground resistance alarm setting range

    Upper limit: 5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ;

    lower limit:0.0~100mΩ

    Ground resistance setting step1mΩ
    Test time range1~300s
    Test time step1s/step
    Leakage current
    The output voltage1.06 times rated voltage provided by the built-in variable frequency power supply
    Leak type settingDynamic leakage, static leakage, built-in one leakage current human body network, any human body network can be customized
    Output voltage measurement rangeAC 50~280V
    Output voltage frequencyAC 45~65Hz
    Output voltage accuracy±(0.5%×displaying+2words)
    Leakage current measurement range0.05~20.00mA
    Leakage current measurement accuracy± (1.5%× displaying +10uA)
    Leakage current setting alarm rangeUpper limit: 0.05 ~ 20.00mA; lower limit: 0.01 ~ 5.00mA
    Leakage current setting step0.01mA
    Test time range1~300s 1s/step
    Power
    Output voltage1.0 times rated voltage, provided by built-in variable frequency power supply
    Output voltage measurement range / accuracyAC 50~280V ±(0.5%×displaying+2 words)
    Output current measurement range / accuracyAC 0.20~30.00A ±(0.5%× displaying +2 words )
    Active power measurement range / accuracy30~6000W ±(0.5%× displaying +5 words )
    Power setting alarm rangeUpper limit: 3 ~ 6000W , Lower limit: 0 ~ 6000W
    Test time range / resolution1~300s 1s/step
    Low voltage start
    Output voltage0.85 times rated voltage provided by the built-in variable frequency power supply
    Output voltage measurement range / accuracyAC 50~280V ±(0.5%× displaying +2words)
    Starting current measurement range / accuracyAC 0.20~30.00A ±(0.5%× displaying +2 words )
    Current setting alarm rangeUpper limit:0.20~30.00A Lower limit: 0.00~25.00A
    Test time range1~300s 1s/step
    Communication Interface232 485 can Bus TCP / IP interface
    External control methodPLC interface, switch signal
    System appearanceSize:600W*1840H*600Dmm Height with pulley, alarm light
    System standard accessoriesPower cord × 1, foot switch × 1, 30A test clamp × 1, test box × 1, power input line × 1, fuse tube × 1