Sign In | Join Free | My himfr.com
Home > Environmental Test Chamber >

IEC 60068-2-14 Three-Box Thermal Shock Test Chamber 300L Environmental Test Chamber

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap IEC 60068-2-14 Three-Box Thermal Shock Test Chamber 300L Environmental Test Chamber from wholesalers
     
    Buy cheap IEC 60068-2-14 Three-Box Thermal Shock Test Chamber 300L Environmental Test Chamber from wholesalers
    • Buy cheap IEC 60068-2-14 Three-Box Thermal Shock Test Chamber 300L Environmental Test Chamber from wholesalers
    • Buy cheap IEC 60068-2-14 Three-Box Thermal Shock Test Chamber 300L Environmental Test Chamber from wholesalers
    • Buy cheap IEC 60068-2-14 Three-Box Thermal Shock Test Chamber 300L Environmental Test Chamber from wholesalers
    • Buy cheap IEC 60068-2-14 Three-Box Thermal Shock Test Chamber 300L Environmental Test Chamber from wholesalers

    IEC 60068-2-14 Three-Box Thermal Shock Test Chamber 300L Environmental Test Chamber

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN887-300L
    Certification : Calibration Certificate(cost additional )
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 10 Sets / Month
    Delivery Time : 30 days
    • Product Details
    • Company Profile

    IEC 60068-2-14 Three-Box Thermal Shock Test Chamber 300L Environmental Test Chamber


    IEC 60068-2-14 Three-Box Thermal Shock Test Chamber 300L Environmental Test Chamber



    Product information:

    Standard:
    1. GB/T 2423.1-2008 Test A: Low temperature test method;
    2. GB/T 2423.2-2008 Test B: High temperature test method;
    3. GB/T2423.22-2002 Test N: Temperature change test method
    4. GJB/150.3-1986 High temperature test
    5. GJB/150.4-1986 Low temperature test
    6. GJB/150.5-1986 Temperature shock test
    7. IEC 60068-2-14—2009 Test N: Temperature change test method

    Sample description:
    This equipment is suitable for two/three temperature zone tests of various temperature shocks and temperature changes within the performance range.
    PS: Change the 2-temperature zone or 3-temperature zone test mode in the form of pneumatic damper switching (note that the 2-temperature zone mode has temperature range restrictions)

    Technical parameters:

    Volume and size

    VolumeAbout 300L
    Inner chamber size600×650×750(D×W×H) mm
    Outer chamber size2250×2250×2250(D×W×H)mm

    Performance

    Working method

    Pneumatic damper switches between 2 temperature zones or 3 temperature zones

    Test chamber impact temperature range

    +50℃ to +200℃/-65℃ to -10℃

    Preheating temperature range of high temperature chamber

    +20℃ to +220℃

    Preheating temperature range of low temperature chamber

    -75℃ to +10℃

    Temperature fluctuation

    ≤±0.5℃

    Temperature deviation

    ≤±2℃

    Temperature uniformity

    ≤2.0℃

    High temperature chamber pre-heating time

    +RT℃ to 220℃ for about 60 minutes

    Low temperature chamber pre-cooling time

    +RT℃ drops to -75℃ for about 90 minutes

    Temperature restoration time

    ≤5 minutes (damper switching time ≤10s)

    Test requirements

    Supports forward and reverse impact, supports exposure to room temperature for 30 minutes
    Energy saving designThe refrigeration system can adjust the power according to the load size, adopts VRF technology based on the PID+PWM principle (the electronic expansion valve is servo-controlled according to the refrigerant flow rate according to the thermal energy working conditions), and has compressor energy adjustment technology, which can achieve excellent energy-saving effects.
    Extra long defrost technology

    Defrosting technology: 1. Use high-temperature return air from the compressor to defrost the evaporator.
    2. The defrost cycle can be set by the user.
    3. Automatic/manual can be set at will. Automatic impact and defrost during automatic operation. Impact and defrost control can be manually suspended during operation.

    NoiseNoise ≤85dB (measured 1m away from the equipment door by the noise detection device).
    Cooling methodThe equipment is water-cooled
    Structure and materials

    Outer chamber

    Sprayed galvanized color steel plate

    Inner chamber

    SUS#304 stainless steel plate, corrosion-resistant. All seams are continuously TIG welded to ensure no leakage after long-term testing. Key parts are reinforced to ensure no deformation during long-term use.

    Insulation layer

    Made of rigid polyurethane foam and glass wool, it is flame-resistant and fire-proof, and meets environmental protection requirements.

    Chamber door

    Left hinge, right door opening

    Sealing

    Original imported silicone sealing strip

    Switching valves

    A. It is divided into high temperature tank, low temperature tank and test tank. The high and low temperature tank is used for energy storage, and the test tank is the user's experimental area.

    B. The high and low temperature tank is separated from the test tank by a switchable valve. The corresponding valve will be automatically opened upon impact.
    C. There is also an independent ventilation valve, which is activated to introduce ambient air during exhaust (normal temperature recovery).

    Test port

    There are three test round holes with a diameter of 50mm on the left side of the equipment. The round holes have covers and soft plugs according to user requirements.

    Observation window

    The door of the box is equipped with a large heating and sweat-proof 3-layer vacuum glass observation window. There is a light in the observation window for observing the conditions inside the test box.

    Casters

    Four casters with fixed feet

    IEC 60068-2-14 Three-Box Thermal Shock Test Chamber 300L Environmental Test Chamber

    Quality IEC 60068-2-14 Three-Box Thermal Shock Test Chamber 300L Environmental Test Chamber for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)