Sign In | Join Free | My himfr.com
Home > Switch Life Tester >

Circuit Breaker Tripping Characteristics Comprehensive Testing Machine 3 Stations IEC60898-1

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Circuit Breaker Tripping Characteristics Comprehensive Testing Machine 3 Stations IEC60898-1 from wholesalers
     
    Buy cheap Circuit Breaker Tripping Characteristics Comprehensive Testing Machine 3 Stations IEC60898-1 from wholesalers
    • Buy cheap Circuit Breaker Tripping Characteristics Comprehensive Testing Machine 3 Stations IEC60898-1 from wholesalers
    • Buy cheap Circuit Breaker Tripping Characteristics Comprehensive Testing Machine 3 Stations IEC60898-1 from wholesalers
    • Buy cheap Circuit Breaker Tripping Characteristics Comprehensive Testing Machine 3 Stations IEC60898-1 from wholesalers
    • Buy cheap Circuit Breaker Tripping Characteristics Comprehensive Testing Machine 3 Stations IEC60898-1 from wholesalers

    Circuit Breaker Tripping Characteristics Comprehensive Testing Machine 3 Stations IEC60898-1

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN2501-3C
    Certification : Calibration Certificate (Cost Additional)
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 5 Sets Per Month
    Delivery Time : 45 Days
    • Product Details
    • Company Profile

    Circuit Breaker Tripping Characteristics Comprehensive Testing Machine 3 Stations IEC60898-1


    Circuit Breaker Tripping Characteristics Comprehensive Testing Machine 3 Stations IEC60898-1


    Product Information:


    The test equipment is designed and manufactured according to the standard requirements of

    IEC60898-1 clause 9.1, 9.8, 9.9 and 9.10, IEC60947-1 clause 7.2.1 and etc.

    It is made to verify that the circuit-breaker complies with the requirements, which apply 1.13 times, 1.45 times, and 2.55 times the rated current to test to see if it trips within the specified time. The test equipment can also test the instantaneous tripping characteristics of the circuit breaker, that is, apply 3 to 20 times the rated current for the test whether it jumps out of the time. Also meets standard 28-day test requirements.


    It is suitable for online testing of molded case circuit breakers and miniature circuit breakers before leaving the factory. It is a necessary equipment for electrical performance testing of circuit breaker manufacturers.


    Technical parameters:


    Project specificationsParameter content
    Applied standardIEC 60898-1
    Clause9.1, 9.8, 9.9, 9.10
    Control method18.5-inch touch-screen computer operation
    Program languageRussian (provided by client translation)
    Test items

    1. Delay test of miniature circuit breaker

    2. Instantaneous test of miniature circuit breaker

    3. Temperature rise test of miniature circuit breaker

    4. 28-day test of miniature circuit breaker

    Test station

    3 separate isolated chambers

    Chamber 1 is:

    1 delayed tripping station 1.13+1.45In; 2.55In

    1 instantaneous tripping station 3-20In

    1 station testing "28 days"

    1 station testing temperature rise


    Chambers 2 and 3. Each chamber includes:

    1 delayed tripping station 1.13+1.45In; 2.55In

    1 station testing "28 days"

    1 station testing temperature rise

    Input powerAC380V 50Hz 40kVA
    Delay trip parameters
    Output AC current0.35~200A
    Output AC voltage1-5V
    Output current channel3-channel, multi-P circuit breaker contacts are connected in series to test several switches at the same time (max. 3 pcs.)
    Test miniature circuit breaker products0.5~63A
    Current output waveformSine wave (correction equipment current waveform distortion is not more than 5%, system error is not more than 3%)
    Current control methodAutomatic adjustment, the current is set on the touch screen
    Current accuracyLevel 0.5
    Voltage accuracyLevel 0.5
    Transformer ratio200/5A
    Test time1~999999s
    CurrentAfter 1.13 times of current is applied, it quickly and automatically rises to 1.45 times of current in 5 seconds
    FixtureAdopt the terminal method, delayed: one station, instantaneous: one station.
    Instantaneous trip test
    FixtureAdopt the terminal method, delayed: three stations, instantaneous: one station.
    Output currentAC3A~1500A
    Instantaneous tripping currents3-20 In
    Output voltage1-5V
    Output current channels1 channel
    Current accuracy0.5 level
    Resolution≥0.1A
    Instantaneous test time≤0.2s
    Action time upper limit setting1~200ms
    Action time lower limit setting1~200ms
    Test station1 station
    Timing time1~9999ms
    Protective function:Short circuit protection, overload protection, leakage protection
    Temperature rise testUnder normal working conditions, when the circuit breaker is tested according to the specified conditions. The circuit breaker should not be damaged to affect its function or safety of use.
    Temperature measurement channel32channels, temperature resolution: 0.1 degrees, 10 channels per chambers (two channels measure the ambient temperature inside the chamber), 2 spare temperature channels
    ThermocoupleT type or K type
    Current0.5~63A
    VoltageAC 30V
    Testing time0-9999 hours
    Temperature curveComputer display with temperature data logging table
    Temperature measurement range0~200 degrees
    28-day test
    Test programThe sample is supplied with AC 30V and rated current, the power-on time is 21 hours, the power-off time is 3 hours, and the cycle is 28 times. The terminal temperature is measured during the last power-on cycle, and compared with the initial measured temperature, the temperature rise value is compared with the standard requirements. After the temperature rise measurement, the current rises to the tripping current value in 5 seconds, and the circuit breaker should trip within the given/preset time.
    Output voltageNot less than AC30V, adjustable
    Output AC currentAC 0.5-125A
    Power on timePower-on time 0-99h, can be preset
    Power off time0-99h can be preset
    Number of cycles0-9999 times can be preset
    Tripping timerecordable
    Tripping current1.0~200A
    Evaluation of results

    1. Whether the circuit breaker tripped during the test or not. If it tripped, it failed; if it did not trip, it passed.

    2. Temperature rise comparison, if it exceeds the standard value by 15K, it is defective; if it does not exceed the standard value, it is acceptable.

    3. After the current rises to the tripping current, if it trips within the given/preset time, it is acceptable; if it exceeds the given/preset time or does not trip, it is defective.

    Configuration
    Connecting cableWires for temperature rise test: 1, 1.5, 2, 2.5, 4, 6 and 10, each specification has a length of 1 meter, and match 5 PCS for each specification; 16, 25, 35, and 50, each specification has a length of 2 meter, and match 5 PCS for each specification
    ThermocoupleType K, 32pcs, 2m length each pcs
    Temperature control in chambers

    3 pcs, for heating the chamber to (RT+5~50°C)

    heating the chamber to (RT+5~50°C)

    3 heating elements in each chamber.

    Control system for setting and maintaining temperature for each chamber.

    3 regulators are installed on the control panel.

    HardwareComputer display greater than 18.5 in, with WIFI
    Threading holeEach workstation is equipped with threading holes for easy connection with instruments outside the box
    SoftwareEditable program segments, capable of forming curves, generating reports, and printable

    Equipment characteristics:

    The equipment chamber is welded with high-quality steel, the plate is coated and sealed, and the surface is anti-static, anti-rust, and anti-corrosion coated. The upper part of the equipment is equipped with a panel, a power switch, and a variety of wire ends (for delay tripping test). The equipment is reasonably designed and used with the advantages of convenience, simple operation, reliable performance and beautiful appearance.


    According to the delayed tripping of standard IEC60898-1 clause 9.10.2.1 or 9.10.2.2, the three chambers in SN2501-3C can be tested independently at the same time. According to the instantaneous test of IEC60898-1 clause 9.10.3.2-9.10.3.4, it can only be tested in chamber 1.


    Test typeChamber 1Chamber 2Chamber 3
    Delay tripping test
    Instantaneous tripping test

    Chamber 1, Chamber 2, and Chamber 3 are independent and can be freely combined for testing.

    Note: The delay and instant of box 1 cannot be tested at the same time.

    Chamber 1 instantaneous trip test and 28-day test cannot be performed at the same time.


    Temperature rise and 28-day test procedure compatibility


    Test typeChamber 1Chamber 2Chamber 3
    Temperature rise
    28-day test procedure

    The temperature rise test and the 28-day test are compatible with each other to and can be performed simultaneously within each chamber and also can be performed independently in different chambers.

    Testing can be carried out both simultaneously and at different times relative to other cameras chambers.

    In different chambers can be carried out simultaneously and independently different types of tests from those provided.

    Each chamber is equipped with a heating device, with a temperature control range of RT+5~50°C, so that the model samples in the chamber can be used at normal ambient temperatures, and includes a three-way ambient temperature monitoring function.

    The software must allow the execution of any test program to be terminated at any time without having to wait for the standard procedure to complete, retaining the results obtained at the time of termination.


    Test principle:

    This test equipment adopts the principle of low voltage and high current output, uses the large current in the machine to isolate the output current of the transformer, sets the current size through the touch screen, and the constant current source adjusts the size of the output current of the transformer, which has the function of automatically stabilizing the current. Set the test time through the touch screen display and compare the test trip time to judge the quality of the circuit breaker.