Sign In | Join Free | My himfr.com
Home > Battery Testing Equipment >

Electric Vibration Test System For Find Early Battery Failure And Simulate Working Condition

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Electric Vibration Test System For Find Early Battery Failure And Simulate Working Condition from wholesalers
     
    Buy cheap Electric Vibration Test System For Find Early Battery Failure And Simulate Working Condition from wholesalers
    • Buy cheap Electric Vibration Test System For Find Early Battery Failure And Simulate Working Condition from wholesalers
    • Buy cheap Electric Vibration Test System For Find Early Battery Failure And Simulate Working Condition from wholesalers
    • Buy cheap Electric Vibration Test System For Find Early Battery Failure And Simulate Working Condition from wholesalers
    • Buy cheap Electric Vibration Test System For Find Early Battery Failure And Simulate Working Condition from wholesalers

    Electric Vibration Test System For Find Early Battery Failure And Simulate Working Condition

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN553-EV220H100VCS5X-4
    Certification : Calibration Certificate (Cost Additional)
    Price : Customized
    Payment Terms : T/T
    Supply Ability : 5 Sets Per Month
    Delivery Time : 1 Month
    • Product Details
    • Company Profile

    Electric Vibration Test System For Find Early Battery Failure And Simulate Working Condition


    Electric Vibration Test System Used For Find Early Battery Failure And Simulate Working Condition


    Product Information For Electric Vibration Test System:


    Environmental Stress Screening (DCS) is extremely effective in eliminating potential product defects. In the development stage, it becomes a magic weapon to find product design defects to achieve reliability growth; in the production stage, it becomes an important means to reduce production costs and create excellent products.

    The DCS project will be applied during product development and production, which can greatly improve product reliability and reduce maintenance costs. Applying DCS during development can greatly save testing time and cost, thereby eliminating or reducing hidden defects before testing. The benefits for producers include: insight into reliability problems in products or processes, so as to eliminate reliability problems from products and processes, reduce production costs and save resources.

    Vibration test can be used to find early battery failure, simulate actual working condition assessment and structural strength test. The product has a wide range of applications, wide application range, remarkable and reliable test effect. It is an ideal battery-specific vibration test for battery manufacturers, quality inspection departments and research institutes. Test Equipment. It is suitable for vibration testing of various types of single cells and battery packs such as charging treasures, lithium-ion, nickel-metal hydride, nickel-cadmium, lead-acid, and nickel metal hydride.

    Vibration tests can also be used for fatigue tests of products for life assessment of products.


    System working diagram For Electric Vibration Test System:



    Technical Performance Indicators of Each Component:


    Vibration Generator (Model: (DV-300) / Power Amplifier (Model KA-3)
    Sine thrust22000N (2200kg.f)
    Random thrust22000n (2200kg.f)
    Impact thrust44000N (4400kg.f)
    Frequency rangeDG~3000Hz
    Continuous displacement51mm
    Shock displacement (maximum displacement)51mm
    Maximum speed2m/s
    Maximum acceleration981m/s2 (100g) (no load)
    Moving coil diameterΦ320mm
    1st order resonance frequency3200 hz±5%
    Allowable eccentric moment≤2500N·cm
    Equivalent mass of moving parts20kg
    Load connection point13
    Table screw size (standard)M8
    Table screw layout (diameter, circumference)13-M8 deep 16mm
    Axial isolation frequency<2.5Hz
    Maximum load400kg
    Flux leakage≤1mt
    Ambient temperature0~40℃
    Table body size (without packaging) (L×W×H) approx.1200mm×870mm×1100mm
    Table weight (without packaging) approx.1600kg
    Amplifier output22kva
    Snr>65db
    System protection

    1. power amplifier overvoltage protection

    2. system timing protection

    3. power amplifier undervoltage protection

    4. zero signal protection (reset)

    5. over-displacement protection

    6. leakage protection

    7. platform overheating protection

    8. excitation fuse protection

    9. module overheating protection

    10. external timing protection

    11. output over-current protection

    12. external zero signal protection

    13. output overvoltage protection

    14. interlock protection of horizontal sliding platform

    15. module overcurrent protection

    16. thermal relay overload protection

    17. module timing protection

    18. power amplifier power-on soft start protection

    Rated output voltage100Vrms
    Output current220A
    Input resistance≥15kω
    Input signal voltage≤1.5rms
    Power amplifier efficiency>90%
    Harmonic distortion (resistive load)<1.0%
    Output voltage measurement error≤5%
    Output current measurement error≤5%
    Output current crest coefficient≥3
    DC stabilityThe zero drift of the output terminal is not more than 30mv/8h
    Frequency range1-120000hz: ±3db; if gain: ≥80
    DC/AC conversion efficiency>92%
    Load natureResistive, capacitive, inductive any
    Parallel current sharing unbalance≤2.8%
    Mean time between failures (MTBF)>3500h
    Cooling methodForced air cooling
    Power supplyAc 3-phase 50hz 380v±10%
    Dimensions (without packaging) (L×W×H) approx.850mm×580mm×1920mm
    Amplifier weight (without packaging) approx.500kg
    Fan (Model: FJ-2000)
    Fan power7.5kw
    Air volume67.5m3/min
    Duct diameter200mm
    Duct length4.5m
    Wind pressure8800pa
    Dimensions (without packaging) (L×W×H) approx.500mm×520mm×650mm
    Weight (without packaging) approx.200kg
    Horizontal slid table (Model: SC-0505)
    Table size1000×1000mm (square)
    Equivalent mass (maximum load bearing)About 150kg
    Upper limit frequencySine 2000hz, random 2000hz
    Table materialMagnesium Aluminum Alloy
    Vertical extension table (model: TB-0505)
    Table size1000mm×1000mm (square)
    Equivalent mass (maximum load bearing)About 143kg
    Upper limit frequencySine 800hz, random 2000hz
    Table materialMagnesium Aluminum Alloy

    Controller Overview and Main Technical Parameters:


    1. Technical indicators and functions

    1.1. Technical indicators and functions of the sinusoidal control measurement system:

    Frequency range:DC-22000Hz
    Crossover point:32 segments, and equal displacement, constant speed and constant acceleration can be set arbitrarily
    Frequency display:The vibration test curve set by the man-machine dialogue can be directly displayed on the screen, and the vibration curve can be displayed in real time during the vibration test, and the error dB at that time can be continuously displayed.
    Output voltage:7Vrms
    Sweep mode:linear, logarithmic
    Sweep rate:0.1-10oct/min
    Control precision:±0.5dB
    Dynamic range:79dB
    Control method:Peak value, average value, effective value, tracking filter
    Vibration mode:Fixed frequency, frequency sweep (linear, logarithmic), pause, resume, return
    Filtering form:Offset anti-aliasing filter (eight stops) passband 0.2dB/oct
    Signal form:Sine wave
    Waveform Distortion:≤0.5%

    Setting function: The test specifications set by the man-machine dialogue can be saved for reuse.

    The controller can be mounted on the rack and integrated with the power amplifier cabinet, or it can be separated from the power amplifier cabinet.

    1.2. Technical indicators and functions of random control measurement system:

    Frequency range100,200,400,500,1000,2000,4000,5000Hz
    Resolution100,200,400,800 lines
    Drive spectrum dynamic range60dB
    Control spectral dynamic range40dB
    Loop time2000Hz, 400 lines single channel 0.6 seconds
    Power spectrum control accuracy±1dB (90% confidence level)
    RMS value control accuracy±0.2dB
    Control channelIndependent channel
    Control methodAverage, maximum
    Spectrum settingsUp to 32 levels, both PSD [(m.s2)2/Hz] and dB/oct can be set

    1. 3. Technical standards and functions of the impact control measurement system:

    WaveformHalf sine, triangle, sawtooth, square wave

    Shock spectrum synthesis

    Frequency range


    5-2000Hz

    Vibration level presetThere are seven vibration levels of -18dB, -15dB, -12dB, -9dB, -6dB, -3dB, and 0dB, and the vibration time of each vibration level is set by the user.
    Upgrade methodThere are two working modes of automatic upgrade and manual upgrade.
    Display functionIt has real-time display and printing functions.
    Protective function:With over-limit alarm, open circuit protection and over-limit automatic shutdown
    Setup function:The test specifications set during man-machine dialogue can be saved for repeated use.
    Measuring range:0-200g is divided into eight gears 1, 2.5, 5, 10, 25, 50, 100, and 200g range automatic shifting.
    Filtering form:Programmable anti-aliasing filter (eight levels) passband 0.2dB, stopband -55dB/oct.
    Signal form:True random, pseudo random.

    1. 4. Features and technical indicators of USB01 card

    Full-scale input16-bit 16-channel single-ended A/D, speed 400KS/S, +/-5V
    Full-scale output1 channel 16-bit D/A, +/-5V
    Win-XPSupport USB1.1 and USB2.0 standard, suitable for Win-2000
    Main controller32-bit 120mhz floating-point digital signal processor (DSP)
    Digital output8 bits
    High-speed continuous acquisition34K*32Bit high-speed static memory
    Clock signal output819.2K filter
    Input channel2-channel single-ended
    Analog input signal voltage rangeBipolar +/-5V
    Resolution16 bits
    A/D conversion time2.5 microseconds
    Acquisition rate400khz
    PrecisionBetter than 0.015%
    Non-linear deviation<4 LSB
    Data Format16-bit two's complement
    Input resistance10MΩ
    A/D conversion trigger modeCommand, timer
    D/A output signal voltage rangeBipolar +/-5V
    D/A resolution16 bits
    D/A conversion time5 microseconds
    PrecisionBetter than 0.015%
    Non-linear deviation<4 LSB
    Data Format16-bit two's complement
    Output resistance<0.1 Ω
    Main controller32-bit 120mhz floating-point DSP TMS320VC33
    System clock40.96khz
    Two 32-bit timer/countersUsed for D/A and A/D timing
    Digital output8 bits (TTL level)
    Clock output819.2khz
    Power consumption<2.5W (5V, 500ma)