ISO 5151 60K BTU Computer Control Dual Code Air - Enthalpy Calorimeter

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap ISO 5151 60K BTU Computer Control Dual Code Air - Enthalpy Calorimeter from wholesalers
     
    Buy cheap ISO 5151 60K BTU Computer Control Dual Code Air - Enthalpy Calorimeter from wholesalers
    • Buy cheap ISO 5151 60K BTU Computer Control Dual Code Air - Enthalpy Calorimeter from wholesalers
    • Buy cheap ISO 5151 60K BTU Computer Control Dual Code Air - Enthalpy Calorimeter from wholesalers
    • Buy cheap ISO 5151 60K BTU Computer Control Dual Code Air - Enthalpy Calorimeter from wholesalers
    • Buy cheap ISO 5151 60K BTU Computer Control Dual Code Air - Enthalpy Calorimeter from wholesalers

    ISO 5151 60K BTU Computer Control Dual Code Air - Enthalpy Calorimeter

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN331C-60KD
    Certification : Calibration Certificate (Cost Additional)
    Price : Customized
    Payment Terms : L/C, T/T
    Supply Ability : 1 Sets Per Month
    Delivery Time : 3 Months
    • Product Details
    • Company Profile

    ISO 5151 60K BTU Computer Control Dual Code Air - Enthalpy Calorimeter


    ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter


    System introduction:


    The air enthalpy calorimeter test chamber consists of an indoor side chamber (A chamber) and an outdoor side chamber (B chamber). The refrigerating capacity, heating capacity and other performance of the air conditioner are tested by testing the parameters of temperature, pressure and electrical performance of the laboratory. The device can be used to test the performance of various window type, split type, independent type, ceiling box type and duct type air conditioners, and can also be used for related tests and extended tests under other standard operating conditions to meet the needs of product sampling inspection and product development. The laboratory has two stations, can simultaneously test two sets of not more than 30KBtu single-phase prototype (to ensure that the total is not greater than 60K BTU), if only test a prototype once, the prototype can reach 60K BTU, but should not be greater than 60K BTU.


    Testing items:


    Rated cooling capacity (T1, T2, T3).

    Rated heating capacity (high, low, ultra low)

    Airflow

    Dehumidifying capacity

    Input power

    ► EER(COP)

    Frequency

    electric current

    Voltage


    Types of UUT and environment:


    Unit under test (UUT) type

    - Split type

    - Windowed

    - Freestanding

    - Ceiling Box

    - Duct type

    - Inverter air conditioner


    ► Measurement range of UUT

    - Test Capability Range:

    - Total cooling capacity: 6000 ~ 60000 Btu / h

    Cooling capacity of station A: 6000 ~ 60000 Btu / h

    Cooling capacity of station B: 6000 ~ 30000 Btu / h

    - Heating capacity: 6000 ~ 60000 Btu / h

    Heating capacity of station A: 6000 ~ 60000 Btu / h


    - Airflow Range

    - Air flow rate A: 300 ~ 4000 m3 / h

    Air volume B: 200 ~ 2000 m3 / h

    - Overall Dimensions: Window: Width: Up to 1000 mm Depth: Up to 800 mm Height: Up to 1000 mm

    Split type: width: less than 1000 mm depth: less than 500 mm height: less than 2000 mm

    - Electrical parameters

    - Single-phase power: 0 ~ 5 kW

    Single phase voltage: 0 ~ 300 V

    Single phase current: 0 ~ 20 A

    Frequency: 50 / 60 Hz

    - Power factor: 0 ~ 1


    Major test conditions

    No

    Testing Item

    Indoor side(℃)

    Outdoor side(℃)

    Dry Bulb

    Wet Bulb

    Dry Bulb

    Wet Bulb

    1

    Rating Cooling

    T1

    27

    19

    35

    24

    T2

    21

    15

    27

    19

    T3

    29

    19

    46

    24

    2

    Maximum Cooling

    T1

    32

    23

    48

    32

    T2

    27

    19

    35

    24

    T3

    32

    23

    52

    31

    3

    Freeze-up

    T1

    21

    15

    21

    15

    T2

    21

    15

    10

    8

    T3

    21

    15

    21

    15

    4

    Minimum Cooling

    21

    15

    18

    12

    5

    Enclosure Sweat

    27

    24

    27

    24

    6

    Rating Heating

    High

    20

    15

    7

    6

    Low

    20

    15

    2

    1

    Extra Low

    10

    8

    -5

    -6

    7

    Maximum Heating

    27

    19

    24

    18

    8

    Minimum Heating

    20

    15

    -7

    -8

    9

    Automatic Defrost

    20

    12

    2

    1

    Sinuo is a diversified high-tech enterprise integrating testing equipment, scientific research and teaching equipment, all kinds of non-standard customized equipment, and integrating independent R & D design, production and sales, installation and commissioning, after-sales maintenance. Company technical staff has accumulated rich practical experience.


    ISO 5151 60K BTU Computer Control Dual Code Air - Enthalpy Calorimeter

    Quality ISO 5151 60K BTU Computer Control Dual Code Air - Enthalpy Calorimeter for sale